SuperAPI AI Directory

simulink-linearize

General & other

View repository

Updated 10-16 09:31

About this skill

Simulink Linearization

Extract linear time invariant (LTI) or linear parameter varying (LPV) models from Simulink using linearize and related APIs from Simulink Control Design.

When to Use

  • Obtaining a linear model (tf, ss, zpk) from a Simulink model
  • Batch linearization across operating points and parameter variations
  • Building LPV models with ssInterpolant
  • Debugging linearization results (zero gain, unexpected dynamics)
  • Extracting multiple LTI systems with a single model compile

When NOT to Use

  • Frequency response estimation from simulation — use simulink-frequency-response for frestimate-based fallback
  • No Simulink model is involved

Workflow

The linearization pipeline has four stages. Not every task requires all stages.

1. Define I/O Points 2. Operating Point  →  3. Linearize  →  4. Debug  
    (root level/linio)   (findop/operspec)     (linearize)     (advisor) 

Stage 1: Define Linearization I/O Points

Determine I/O points using this decision sequence. Use the first case that applies:

Case A — IO points can be inferred from prompt or model context:

Use the first sub-case that matches:

  1. User specifies explicit I/O signals or blocks (e.g., "from r to y") → define linio points. All linio points must reference a block's output port. If a candidate block has no output ports (Outport, Terminator, Scope) → trace upstream to find the source block and port with model_read.

    io = [linio(sprintf("%s/InputBlock", mdl), 1, "input"); ...
          linio(sprintf("%s/OutputBlock", mdl), 1, "output")];
    
  2. User targets a specific block or subsystem (e.g., "linearize the Controller") → Use the block path as the io argument signaling linearize to perform open-loop linearization of the block

    io = sprintf("%s/Controller", mdl);
    
  3. Model has existing linearization points → io = getlinio(mdl); — use if non-empty.

  4. Root-level Inport/Outport blocks exist → omit linio. The linearize command will linearize about the model's root-level I/Os. Use model_read at root scope (depth "0") to confirm root-level Inport/Outport blocks exist.

Case B — Cannot determine IO points:

If none of the above apply → do not guess. Ask the user which signals to use as linearization inputs and outputs. Present the available blocks/signals from the model to help them decide.

Block path rules:

  • Use sprintf for block names containing special characters (newlines, commas):
    blkPath = sprintf("%s/Integrator,\nSecond-Order", mdl);
    io = linio(blkPath, 1, "output");
    
    sub.Name = sprintf("%s/My\nBlock",mdl);
    sub.Value = replacement_lti;
    
    sys = linearize(mdl, io, sub);  
    

Stage 2: Operating Point

Determine where to linearize. Choose one:

Situation Approach
Model ICs Skip — linearize uses model initial conditions
Steady-state trim operspec → configure → findop(mdl, opSpec, findopOptions(DisplayReport="off"))
Need snapshot from simulation linearize(mdl, tSnapshot)
Batch over parameter grid Array of operspec objects → findop(mdl, specArray, params)
Operating points known Array of operpoint objects → configure

For batch workflows, use copy to create the operating point array:

% assign varied variable to workspace
myvar = 0;
% create base spec
opBase = operspec(mdl);
opBase.States(1).Known = true;
% define param to vary
nPts = 5;
params.Name = "myvar";
params.Value = linspace(-pi, pi, nPts);
for i = nPts:-1:1
    opArray(i) = copy(opBase);
    opArray(i).States(1).x = params.Value(i);
end
ops = findop(mdl, opArray, params, findopOptions());

Stage 3: Linearize

sys = linearize(mdl, OPTIONAL_ARGS);

Each input argument to linearize is optional (beside mdl).

sys = linearize(mdl, io, op, params, blocksub, opts);
Argument Required Behavior if Provided Behavior if Omitted
mdl Y Model to linearize NA
io N linearize at I/O points Linearize at root level I/Os
op N Operating points OR times to linearize Linearize at model IC
params N Vary parameters for each linearization No variation
blocksub N User specified block linearizations Blocks have Simulink linearization
opts N User specified linearizeOptions Default options

Multi-rate models default to the LCM sample time. Use the SampleTime option to specify linear model sample time:

opts = linearizeOptions(SampleTime=0);
sys = linearize(mdl, io, opts);

Batch linearization for LPV:

opts = linearizeOptions(BatchConsistency="on", StoreOffsets="system");
sysArray = linearize(mdl, io, ops, params, opts);
lpvSys = ssInterpolant(sysArray);

When StoreOffsets="system", offsets are embedded in each model of the array. Call ssInterpolant(sysArray) with no offset argument.

Define SamplingGrid if one is not generated from linearize (params argument is omitted).

Multiple transfer functions (single compile) with slLinearizer:

sllin = slLinearizer(mdl);
addPoint(sllin, ["r", "y", "e", "u"]);
T = getIOTransfer(sllin, "r", "y");
S = getSensitivity(sllin, "e");
L = getLoopTransfer(sllin, "u", sign);

Stage 4: Debug (Linearization Advisor)

Use when linearization returns zero gain or unexpected results.

opts = linearizeOptions(StoreAdvisor=true);
[sys, ~, info] = linearize(mdl, io, opts);
advisorResult = advise(info.Advisor);

Always capture the output of advise — calling without an output argument launches the UI.

Inspect problematic blocks:

problematic = find(advisorResult, linqueryHasDiagnostics());
for i = 1:numel(problematic.BlockDiagnostics)
    diag = problematic.BlockDiagnostics(i);
    fprintf('%s: %s\n', diag.BlockPath, join(string(diag.DiagnosticMessages), newline));
end

Common advisor findings and resolutions:

  • "linearization has zero input/output pair" → Change operating point, or use block substitution if reasonable to do so
  • Block with hard discontinuity (PWM, relay, dead zone, non-floating point signals) → Analytical linearization will be zero. Fall back to frequency response estimation
  • Reference diagnostic message for other potential fixes

Convert if needed

tfSys = tf(sys);      % Transfer function
zpkSys = zpk(sys);    % Zero-pole-gain

LPV Validation

For LPV models, simulate and compare against Simulink:

[y, t] = lsim(lpvSys, u, tVec, x0, paramTrajectory);

Key Functions

Function Purpose Available From
linearize Linearize Simulink model R2006a
linearizeOptions Configure linearization algorithm R2006a
linio Define linearization I/O points R2006a
getlinio Get I/O points defined in model R2006a
operpoint Create operating point with manual state values R2006a
operspec Create operating point specification R2006a
findop Trim or snapshot operating point R2006a
slLinearizer Batch/multi-transfer-function interface R2013b
getIOTransfer Closed-loop transfer function from slLinearizer R2013b
getSensitivity Sensitivity function from slLinearizer R2013b
getCompSensitivity Complementary sensitivity from slLinearizer R2013b
getLoopTransfer Open-loop transfer from slLinearizer R2013b
advise Run linearization advisor R2017b
ssInterpolant Build gridded LPV/LTV model R2023a

Common Mistakes

Mistake Why It's Wrong Correct Approach
Using linmod, linmod2, linmodv5 or dlinmod Legacy API, limited features Use linearize or slLinearizer
Not using advise when result is zero Leads to trial-and-error Enable StoreAdvisor="on", call result = advise(info.Advisor)
Using Outport/Terminator/Scope as linio point Blocks without output ports cannot be specified as linearization I/O — errors Trace upstream to find the source block that feeds it
opSpec(i) = opSpecBase in a loop operspec is a handle class — this aliases, not copies Use opArray(i) = copy(opBase)
Omitting BatchConsistency in batch State ordering may vary across operating points Always set BatchConsistency="on"
Calling ssInterpolant without offsets LPV model requires offsets Use StoreOffsets="system"
Calling advise without output arg Launches Model Linearizer UI (hangs in non-interactive sessions) Always use result = advise(advisor)
Repeated linearize calls for different I/Os Recompiles model each time Use slLinearizer for single compile
Manual trial-and-error for zero results Wastes time, may not find root cause Use advisor diagnostics — identify the problematic blocks

Conventions

  • Always: Capture the output of advise() to prevent UI launch
  • Always: Use copy(opSpec) for batch operating point arrays, not assignment
  • Always: Set BatchConsistency="on" for batch linearization destined for LPV
  • Always: Set StoreOffsets="system" when building LPV models with ssInterpolant
  • Prefer: slLinearizer when extracting multiple transfer functions from one model
  • Never: Place linio on blocks without output ports (Outport, Terminator, Scope) — trace upstream to find the source block
  • Never: Use linmod, linmod2, linmodv5 or dlinmod — these are legacy

Copyright 2026 The MathWorks, Inc.