SuperAPI AI Directory

jinko-task-debug-solving-errors

Testing & quality

View repository

Updated 11-16 18:15

About this skill

Debug solving errors

Find the failure mechanism and validate a repair against the original scenarios. Use jinko-model for model edits and jinko-trial for trial mechanics. Preserve source revisions and perform experiments on copies within the authorized scope.

PREREQUISITE: This skill needs an initialized jinko-sdk connection and an SDK satisfying its metadata.requires_sdk range. Run the jinko-sdk-setup skill (../jinko-sdk-setup/SKILL.md) and proceed only once its check passes. Use JINKO_API_KEY when it is set. Otherwise, obtain a fresh session code before this skill's SDK process, as instructed by the setup skill. Also check that python -m jinko.cli.debug_solving --help works. If the command is missing, upgrade jinko-sdk. Do not replace the command with private transport calls.

Collect before changing

Run the deterministic diagnostic command into a new directory. It does not edit items or start trials. A model solve requires --run-simple-solve explicitly.

python -m jinko.cli.debug_solving --model-sid cm-... --out debug/model
python -m jinko.cli.debug_solving --trial-sid tr-... --revision 2 \
  --telemetry --out debug/trial

For one authorized model probe, select representative outputs and preserve exact formula overrides in a JSON object. The command uses at most ten output slots. Available telemetry fills remaining slots; absent metrics are reported as such.

python -m jinko.cli.debug_solving --model-sid cm-... --revision 4 \
  --run-simple-solve --timeseries-id Time --timeseries-id Drug \
  --overrides-json case.json --telemetry --out debug/probe

Use --patient-id to retain an exact patient row from the bound population; this reads the population. The bundle also records the bound protocol and trial options. Reconstruct the scenario from all three. Do not assume the model head, its default settings, or a bare patient row represents the failed trial arm. --arm-id limits telemetry downloads, not the original failure inventory.

Read report.json and collection errors before interpreting the bundle. Exit codes are 0 for successful collection without detected failure, 1 for a reported model/solve/patient failure, and 2 for incomplete collection or invalid input. Neither exit 0 nor finite outputs establish numerical or scientific validity.

Choose the investigation

  • Slow or timed out: separate client wall time, solver time, compilation, and incomplete evidence. Treat at least 15 seconds as a configurable signal. Inspect the solver, tolerances, state scales, maximum step, and auxiliary events before choosing a bounded experiment.
  • Patient/arm subset: group raw errors by patient and arm, compare exact inputs with a successful control, and retain the full failure set. Shared derivative names can conceal different upstream causes.
  • Non-finite derivative: trace upstream expressions, including division, logarithms, roots, fractional powers, and switched branches. The reported derivative is not necessarily the first invalid expression. The reported last solved time may be an earlier output point.
  • Setup or export error: inspect trial-context sanity, formulaic descriptor overrides, unit mode, and event schedule. Keep unit/conversion defects separate from runtime defects. For failed exports, preserve the error and use native JSON plus options when supported.

Read investigation guidance for telemetry meaning, controlled solver experiments, and independent replication after a full timeout.

Verify and report

Change one cause at a time. Compare the original failing case, a successful control, and then all original subjects and arms. Check finite trajectories, physiological constraints, event behavior, and numerical sensitivity. Halve the maximum step or tighten tolerances for a justified comparison; do not call an unconverged candidate validated merely because every subject completes.

Report evidence, hypotheses, copy-level changes, remaining failures, and open scientific questions separately. Record pins, settings, override warnings, metrics, and comparison tolerances. Never silently drop failing patients, loosen accuracy to obtain completion, or apply a model-specific clamp to other models.