Goal: turn "looks fine" into repeatable tool evidence, and honestly distinguish between pass, fail, unverifiable, and planned.
Start in 30 seconds
Currently planned only means Codeguard can recognize .ets, not that an executable gate exists.
- Clearly report "recognized, but currently not verifiable by Codeguard".
- Keep the project's existing IDE, compiler, or platform diagnostic results; do not fabricate generic commands.
- If checking is necessary, use the target platform's official tools and mark the results as external evidence.
- Only after completing detection, lint, failure samples, and regression tests can the registry be upgraded to stable/beta.
Capability boundaries
✅ Good at
- Recognizing ArkTS (HarmonyOS) files and related user intent.
- Clearly stating the current Codeguard support status and gaps.
- Defining verifiable acceptance criteria for future integration.
⚠️ Requires conditions
- Real target tool or platform diagnostic output.
- At least one failure sample and one passing sample.
- A repeatable non-interactive command or a clear host boundary.
❌ Out of scope
- Do not execute nonexistent generic linter commands.
- Do not write extension recognition as a passing quality gate.
- Do not upgrade support status without running evidence.
When to use
- The user requests checking or fixing ArkTS (HarmonyOS) code specifications.
- AI modified
.ets, requiring pre-commit verification. - CI shows failures related to
ArkTS (HarmonyOS) 工具链. - Need to determine whether a problem can be fixed automatically or must be handled manually.
When not to use
- The main task is learning language syntax, framework design, or business modeling; use the corresponding language professional skill instead.
- The main task is dependency vulnerabilities, security auditing, or license governance; use a dedicated security skill.
- When the user only asks to explain one error and there is no project context, first give a local explanation and do not claim the repository is all green.
Data and security
This skill does not collect, upload, send, or store user code and credentials. By default it only reads local repository configuration and runs local tools; it does not install dependencies over the network, and does not log tokens, passwords, or private source code. Before any automatic fix, check the diff first; destructive or large-scale changes must be explicitly confirmed by the user.
Execution contract
| Item | Current fact |
|---|---|
| Status | planned(since Codeguard V0.5) |
| File extension | .ets |
| Project marker | No dedicated marker file |
| Integration configuration | Subject to the repository's existing configuration |
| Tool readiness | No standalone CLI linter (relies on platform IDE diagnostics) |
| Detection command | 使用命令查找与项目配置检查 |
| lint | 未接入 |
| format/fix | 未接入 |
| Project-level gate | 未接入 |
Standard Workflow
Step 1: Determine the real scope
Confirm the repository root, module roots, generated directories, vendor directories, and user-specified files. For multi-module projects, first list the modules to be scanned; do not guess based on the current directory.
Step 2: Read the project contract
Read the repository's existing configuration and the actual commands in CI. Repository configuration takes precedence over this skill's examples; if the two conflict, report the difference first.
Step 3: Detect tools and versions
Run 对应工具 --version. Missing tools, incompatible versions, or configurations that fail to load are all recorded as "unable to verify," not as pass.
Step 4: Run read-only checks
Run 目标平台官方诊断, recording the command, working directory, exit code, tool version, and the first actionable error.
Step 5: Failure classification
| Type | Typical signal | Handling |
|---|---|---|
| Format | Indentation, whitespace, import order | Formatter allowed; then check the diff |
| Static rules | unused, complexity, naming, dangerous APIs | Minimal semantic fixes; no bulk guessing |
| Configuration | parser/config/schema not found | Fix the integration or report the prerequisites |
| Environment | command not found, version conflicts | Report installation/version requirements; do not install silently |
| Tool internal error | crash, timeout, parser exception | Preserve the original evidence and narrow the reproduction scope |
Step 6: Controlled fixes
Run first 人工最小修复. Handle only issues that are certain and reversible; dependency upgrades, rule exemptions, generated files, and business semantic changes must be explained separately.
Step 7: Verification loop
Rerun the same lint command, then run the project's existing tests and build. Only write "pass" when the command, scope, and exit code are all clear; otherwise write "not run" or "unable to verify."
Rules
- Same-command re-verification: After fixing, the original command that triggered the failure must be rerun.
- Layered evidence: Report lint, format, compile, test, and security separately.
- Minimal changes: Do not refactor along the way, and do not expand a style fix into a business rewrite.
- Configuration first: Do not override the project's existing ignore, dialect, target, or version constraints.
- No fabrication: Tools not run, configurations not seen, and platforms not verified must be clearly marked.
Output template
ArkTS (HarmonyOS) Codeguard 结果
- 范围:<仓库/模块/文件>
- 工具:<名称与版本>
- 命令:<实际命令>
- 状态:PASS / FAIL / UNVERIFIED / PLANNED
- 发现:<按格式/规则/配置/环境分类>
- 修改:<文件与原因;无修改写 none>
- 复验:<命令、退出码>
- 未验证:<测试/构建/平台差异>
Gotchas
- Missing tools are not a pass — must output
UNVERIFIEDand a clear preparation method. - A formatter is not a linter — all-green formatting cannot cover static rules or compilation errors.
- The root directory determines the result — running in the wrong module may miss issues or load the wrong configuration.
- Placeholders are not literal arguments —
{file}Must be replaced with real, authorized paths. - Automated fixes may expand the diff — after fixing, review the diff first, then run the regression gate.
- Generated and vendor directories require an explicit policy — Do not casually scan or modify third-party content wholesale.
Domain pitfalls and fixes
- Domain pitfalls — The current entry is marked as planned; it can only be upgraded after obtaining official HarmonyOS/DevEco diagnostic evidence.
When information is insufficient
Do not just say "please provide more information." First provide a safe read-only inspection plan, and list the specific items that still need confirmation:
- repository/module root directory;
- target tools and versions;
- project configuration files;
- the authoritative commands in CI;
- whether automatic fixes are allowed.
FAQ
Q1: If the tool is not installed, can it be determined that the code has no problems? No. The status must be UNVERIFIED。
Q2: Can ignore or suppression be added automatically? No. Exemptions can only be granted when the user explicitly accepts them and the reason is recorded.
Q3: Why does it still fail after formatting? The formatter only covers formatting; static rules, configuration, compilation, and tests still need to be handled separately.
Q4: Should generated code be scanned? By default, follow the repository configuration; when there are no rules, first exclude generated/vendor code, then explain to the user.
Q5: How can too many changes at once be avoided? First fix in batches by failure category and file, and rerun the original command and review the diff for each batch.
Q6: If it passes locally, can it be said that CI will pass? No. It is also necessary to align CI's versions, environment variables, operating system, and command scope.
Load resources on demand
- When encountering exit codes, failure classification, or exemption decisions, read
references/rules/gate-rules.md。 - When you need to verify this language's registry, toolchain, and project configuration, read
references/tooling/toolchain.md。 - When you need copyable task examples, read by scenario
examples/, and there is no need to load all of them at once.