For GPU clusters on SageMaker HyperPod (Slurm or EKS), AWS ParallelCluster, and self-managed EC2 or EKS. Generic investigation finds the obvious signals; this skill adds what it gets wrong: silent evidence, wrong-headline hardware verdicts, and predictable failures before a long run. Read-only. Never reboot, replace, update, or delete anything, and never read training data, checkpoints, or model weights.
Critical rules R1 to R11 (apply in every mode, in this order)
R1. Answer in one pass, and always leave room to answer. In chat, do not stop to ask a
question and do not hand off to a separate investigation before answering. If an input is
missing, use the default (impact window: last 24 hours; run length: evaluate 24, 48, and
72 hours), state the assumption, and mark dependent checks Needs input. For "slow" or
performance questions with no time given, use the last 72 hours. Offer follow-ups only
after the answer.
Budget the evidence gathering so the answer always gets written. An investigation that
runs out of room before it reports is worth nothing to the operator, and it is worse than a
partial answer because it looks like a failure rather than a finding. So: collect the
mandatory evidence for the mode first (R2, R4, R5, and for Mode P the P1 to P6 core), then
write the report. Pick up the optional checks only with what is left. If you notice you are
deep into tool calls and have not yet produced an answer, stop collecting and report what
you have, marking everything unreached as Not checked with the call that would close
it. Never end a turn with evidence gathered and no verdict.
R2. Inventory and capability profile. HyperPod: sagemaker.DescribeCluster and
ListClusterNodes (paginate). Read NodeProvisioningMode from DescribeCluster: if it is
Continuous, also pull sagemaker.ListClusterEvents for the window (see rule R11), which
is the only timeline source that survives broken log delivery. On any other value the call
is unsupported and must be skipped, not retried.
EC2/ParallelCluster/EKS: ec2.DescribeInstances. For every
GPU instance type: ec2.DescribeInstanceTypes (strip HyperPod ml.): GPU count,
EfaSupported, MaximumEfaInterfaces; per EC2 node, attached efa/efa-only interfaces.
Report <attached> of <max>, where attached = interfaces with InterfaceType efa or
efa-only (the primary ENA interface does not count unless it is efa). HyperPod nodes
are not visible to DescribeInstances: say so. On NVSwitch types, search every log source
found under rule R4 for Started "Nvidia Fabric Manager" before saying it is not confirmed.
R3. Node identity survives replacement. A HyperPod reboot keeps the instance ID; a replace
gives the node a new instance ID in the same instance group, so the current ID will
never appear in the replace request. Query CloudTrail by event name, not by instance
ID: cloudtrail.LookupEvents with LookupAttributes=[{AttributeKey: EventName, AttributeValue: BatchReplaceClusterNodes}], then again for BatchRebootClusterNodes,
BatchDeleteClusterNodes, and UpdateCluster, with StartTime = window start minus 6
hours and EndTime = now as full ISO-8601 UTC timestamps, paginating with NextToken.
Keep events whose requestParameters.clusterName is this cluster. A nodeIds entry
that is not in the current ListClusterNodes output was replaced; the instance group
whose node has a LaunchTime just after that event is the replaced group. That operator
or automatic call is the explanation for the node going Pending (Branch E), not hardware.
R4. Find every log source by substring, not prefix. Call logs.DescribeLogGroups with
logGroupNamePattern (case-sensitive substring) = the cluster name, then again for
kernel, messages, syslog, journal, and gpu, paginating with nextToken. Never
search only /aws/parallelcluster or /aws/sagemaker prefixes: customer pipelines use
other names (for example /aws/<pipeline>/<cluster>/kernel). Evaluate every source found.
R5. Prove coverage before any "no errors". For each node and source: find the stream that
carries kernel: lines, then bin that exact stream by hour across the window padded by
one hour. Always name the evidence you used: quote the full log group name and the exact
log stream name for every node in the coverage table, and again in the answer text. A
coverage claim without the group and stream it rests on is not auditable, so the operator
cannot re-run it. Any empty hour means Not observable for that hour. First and last event times
are not proof, and the time of the last kernel: line is not when logging stopped:
a healthy kernel goes quiet. Liveness comes only from the hourly bins of all lines in
that stream. A node is Measured if one source passes. HyperPod: a missing
SagemakerHealthMonitoringAgent/<group>/<instance-id> stream means No HMA detections
when the cluster log group is otherwise live. NCCL transport with no NCCL INFO lines
anywhere is Not observable; never infer it from the instance type.
R5a. Name every resource you looked at, by ID. A finding the operator cannot re-run is
not a finding. Whatever you analysed, put its identifier in the answer: the FSx file system
(fs-...) behind any storage claim, the instance IDs (i-...) behind any node claim, the
cluster name, the capacity reservation (cr-...) behind any capacity claim, and the log
group and stream behind any log claim as R5 already requires. "The file system was
saturated" or "the metrics looked fine" names nothing and cannot be checked. This applies
to the resource you cleared as much as the one you blamed, since ruling something out is
only useful if the reader knows what was ruled out.
R6. Verdict per node, headline to match. REPLACE, REBOOT, LEAVE ALONE, MONITOR, or
NOT OBSERVABLE, against the evidence bar in references/incident-branches.md (Step 4b).
Application-class Xids (for example 13, 31) or HMA reason: XidUserAppError with the node
Running is LEAVE ALONE. Never headline "hardware error" unless the verdict is REPLACE
or REBOOT on hardware grounds.
R7. Label every cause Proven (measured signal on the affected node, before the failure,
nothing competing) or Hypothesis (to validate) with the one confirming measurement. A
spike at the same time is correlation. FSx without a saturated metric is not a proven cause.
Only a Proven cause may be called the root cause, in the headline or in a branch table.
Otherwise write Leading hypothesis: <cause>, or Root cause: Not observable when the
deciding evidence is missing (for example a dead control-plane log). Never write "Proven
mechanism" for something whose trigger or removal path you did not observe.
Utilization metrics from FSx (NetworkThroughputUtilization, DiskIopsUtilization, and
similar) and GPUPowerUtilization are already percent from 0 to 100: a value of 0.9 is
0.9 percent. Quote the raw value with a percent sign.
R8. Recovery questions always state three things: whether automatic node recovery is on
(NodeRecovery), what it does (reboot or replace the node), and that the job resumes
only with checkpoints plus the orchestrator's auto-resume (Slurm on HyperPod:
srun --auto-resume=1).
R9. Capacity Blocks begin terminating instances 30 minutes before the end time (60 for
UltraServers); blocks end at 11:30 UTC and termination starts at 11:00 UTC on the last day.
For a planned run, write out: usable until = end time minus the lead time; run end = start
plus run length; hours covered = usable until minus start. Give every value as a full UTC
date and time, and check the latest safe start is not already in the past.
R10. Rule out the frequent non-GPU causes in references/cluster-edge-cases.md before
blaming hardware: subnet IP or network interface exhaustion, ParallelCluster bootstrap
failures and protected mode, EFA nodes in a public subnet, a Capacity Block not yet
active, and the FSx maintenance window. HyperPod does not export system metrics to
CloudWatch, so HyperPod GPU activity is Not observable there.
R11. When the logs are dead, ask the control plane. On a HyperPod cluster with
NodeProvisioningMode = Continuous, sagemaker.ListClusterEvents gives you a node and
cluster timeline that owes nothing to a log agent, so it keeps answering when a stream has
gone silent or a node has disappeared. Filter the window with EventTimeAfter and
EventTimeBefore, narrow with NodeId or InstanceGroupName, sort with
SortBy=EventTime, and page through NextToken. Where a Description is not
self-explanatory, DescribeClusterEvent has the detail. Note that the response has no
severity or level field at all, so any grouping you apply is your own and should be
described that way. If NodeProvisioningMode is anything other than Continuous the call
is not supported; write ListClusterEvents not supported in the coverage table and carry
on. What you must not do is report a dead log as "no events" without either trying this
source or saying it was unavailable.
Pick the mode
| The user asks | Mode | Steps to run |
|---|---|---|
| Something failed, hung, slowed, or lost nodes | I: Incident | Steps 1 to 7 |
| "Were there GPU errors?", "Can I trust the logs?" | C: Coverage audit | Steps 1 to 3, then 6 and 7 |
| "Is the cluster ready for a long run?", Capacity Block ending | P: Pre-flight | Steps 1 to 3, then 5P, 6 and 7 |
Workflow checklist
Work through these in order and tick each one as it completes. Skip only the steps the
mode table excludes. Every step below has a matching ## Step N section with its detail.
- Step 1: Scope the request: account, region, cluster or instance IDs, impact window
- Step 2: Build the inventory, capability profile, and one ordered timeline
- Step 3: Prove GPU log coverage per node before looking for errors
- Step 4: Classify each fault and give every node a verdict
- Step 5: Pull metrics and settle the root-cause branch
- Step 5P: Score pre-flight checks P1 to P16 (Mode P only, replaces Steps 4 and 5)
- Step 6: Write the report in the required format
- Step 7: Self-check the finished output, then present it
Step 1: Scope
Account, region, cluster name or instance IDs, workload, impact window (default last 24 hours, stated). Classify the symptom to pick a starting branch (Step 5), but collect evidence for all.
Step 2: Inventory and timeline
Load references/inventory-and-timeline.md for the inventory API calls and the eight timeline sources, and references/cluster-edge-cases.md for the frequent non-GPU causes to rule out under rule R10:
read_skill_resource(skill_id="aiml-gpu-training-cluster-investigation", path="references/inventory-and-timeline.md")
read_skill_resource(skill_id="aiml-gpu-training-cluster-investigation", path="references/cluster-edge-cases.md")
Build one ordered timeline for the window plus 30 minutes each side: node state, HMA detections, Xids, AWS Health, EC2 status and scheduled events, Capacity Block and training plan end times, and CloudTrail cluster changes (rule R3).
Step 3: Coverage audit
Load references/coverage-audit.md for the log-source discovery and hourly coverage queries, and references/nccl-nvlink-efa.md for NCCL transport, NVLink and NVSwitch, and EFA signals:
read_skill_resource(skill_id="aiml-gpu-training-cluster-investigation", path="references/coverage-audit.md")
read_skill_resource(skill_id="aiml-gpu-training-cluster-investigation", path="references/nccl-nvlink-efa.md")
Produce the coverage table and the node capability and fabric table for every affected node. Every row names the full log group name and the exact log stream name that row's verdict rests on, so the operator can re-run the same query. Where no stream carries kernel lines, say which groups you searched and that none did.
Step 4: Classify faults and give node verdicts
Load references/xid-triage.md for the Xid catalog and per-code verdicts, and references/incident-branches.md for the node verdict evidence bar and branches A to F:
read_skill_resource(skill_id="aiml-gpu-training-cluster-investigation", path="references/xid-triage.md")
read_skill_resource(skill_id="aiml-gpu-training-cluster-investigation", path="references/incident-branches.md")
Step 5: Metrics and root-cause branch
Load references/signals-and-thresholds.md for metric names, dimensions, and thresholds:
read_skill_resource(skill_id="aiml-gpu-training-cluster-investigation", path="references/signals-and-thresholds.md")
Pull FSx (correct dimensions per metric), GPU activity (AWS/EC2 GPUPowerUtilization, unit
Percent, or CWAgent), and EFA counters, then evaluate branches A (hardware), B (capacity
lifecycle), C (storage), D (NCCL, NVLink/NVSwitch, EFA), E (cluster change), and F (application,
only after A to E are ruled out), as defined in incident-branches.md. Recommend operator
actions only.
Step 5P: Pre-flight readiness (Mode P)
Load references/preflight.md for pre-flight checks P1 to P16:
read_skill_resource(skill_id="aiml-gpu-training-cluster-investigation", path="references/preflight.md")
Score checks P1 to P16. Lead with FAIL, then RISK. In Mode P this step replaces Steps 4 and 5.
Work the core first, then extend. All sixteen checks together cost more tool calls than a single answer usually has room for, and a readiness question with no verdict is a failed answer however much evidence sits behind it (see R1). So run them in two passes.
The core, which decides whether the run can start at all:
| Check | Question it settles |
|---|---|
| P1 | Does the Capacity Block or training plan outlast the run? |
| P2 | Is there an extension, if it does not? |
| P3 | Is there a spare node to replace a failure? |
| P4 | Is NodeRecovery on? |
| P5 | Are deep health checks enabled? |
| P6 | Is GPU error logging arriving, so a failure during the run is visible? |
Write the readiness verdict as soon as those six are scored. P7 to P16 then refine it, and
each one you reach can only add a RISK, never change a FAIL already found in the core.
Anything you do not reach is reported Not checked with the call that would settle it, which
is an honest answer; silence is not. If the core itself is incomplete, say which part and
give the verdict you can support.
Step 6: Report
Load references/report-format.md for the report template and its rules:
read_skill_resource(skill_id="aiml-gpu-training-cluster-investigation", path="references/report-format.md")
Step 7: Self-check before presenting
Before showing the answer to the user, re-read your own draft and verify each of these. Fix the draft where a check fails; do not present an output that fails one.
- Every "no errors found" statement is backed by a node whose coverage you proved in
Step 3. If coverage was not proven, the wording is
Not observable, not healthy. - Every coverage row names its full log group and exact log stream (rule R5). A coverage claim with no named source is not auditable and must be fixed before presenting.
- Stream names appear as the service writes them, not paraphrased. Search your own draft
for phrases like "the HMA log stream" or "the health agent log" and replace each with
the real name, for example
SagemakerHealthMonitoringAgent/<instance-group>/<instance-id>. This is the easiest check to skip in a short answer and the one that most often makes a finding unreproducible. - Every node verdict still meets the evidence bar that justifies it, re-read from references/incident-branches.md Step 4b.
- The headline matches the verdicts. It does not say "hardware error" unless a verdict
is
REPLACEorREBOOTon hardware grounds (rule R6). - Every cause carries a
ProvenorHypothesis (to validate)label, and anything labelledProvenhas a measured signal on the affected node before the failure (rule R7). Nothing unproven is called the root cause. - Every percentage came straight from the metric without rescaling (rule R7).
- Every absent signal is reported as
Not observablewith what to collect, never as zero or as healthy. - Each recommendation names an operator action, and no mutating API call was made.
- Every number in the answer can be traced to a call you actually made this run.
- Every resource you analysed appears by ID (rule R5a): the
fs-...behind a storage claim, thei-...behind a node claim, thecr-...behind a capacity claim, the cluster name, the log group and stream. This holds for resources you cleared, not just the one you blamed. - There is an actual answer. A verdict or root cause is written down, not just
evidence. If you ran out of room before finishing, the draft still leads with the
verdict you can support and marks the rest
Not checked(rule R1).
State the outcome of this self-check in one line, naming anything you could not verify.
Success criteria
- Coverage table and node capability table for every affected node; no "no errors" without proven coverage.
- One verdict per node with a GPU signal; headline consistent with the verdicts.
- Every cause labelled
ProvenorHypothesis (to validate). - Replaced nodes matched to the operator or automatic action that replaced them.
- Mode P: P1 to P16 scored.
- No mutating API call was made.
References
- HyperPod health monitoring system
- HyperPod deep health checks
- Manually replace or reboot a HyperPod node
- HyperPod Slurm cluster logging
- ClusterInstanceStatusDetails
- How Capacity Blocks work
- EFA security group requirements
- Monitor Capacity Blocks using EventBridge
- FSx for Lustre metrics and dimensions
- NVIDIA Xid catalog
- EC2 accelerator metrics (GPUPowerUtilization)
- DescribeTrainingPlan
- DescribeCapacityBlockExtensionOfferings